Integrated long range reader with built-in access controller
CODE: Nundnet NTI9106XY
Integrated Long range reader with built-in access controller, NTI9106XY compatible with UHF RFID tags EPC Gen II (ISO 18000 – 6C) with the ideal sensing distance of 6-8Meters, with the built-in access control unit supporting two access zone. The compatible frequency ranges are 865~868MHz (EU standard) and 902~928MHz (US standard. The multiple communication ports TCP/IP, Wiegand (de-facto communication ports), RS232, USB, and RS485 are available for system integration while as the relay outputs are available for integration with locking sources like Parking barriers, gates etc.
Integrated Long range reader NTI9106XY is compatible with Nundprox U series of UHF RFID cards and tags.Cards are registered with the built in access controller using master (add & delete) card thereby eliminating the use of external software’s and computers, hence making a perfect standalone unit.
Integrated Long range reader with built-in two door standalone controller | |
UHF reader with built-in two door controller | Users 2000 +100, 2100(users) |
Standalone Operation | 902~928 (USA), 865~868MHz (EU) |
No need of Computer or software | RS232, RS485, USB, Wi-Fi, TCP/IP |
Generic PAC functions | Wiegand 26~37 Interface |
Nundprox M, K, U compliant | IP56 rated |
Data transfer | CE, RoHS |
INTEGRATED LONG RANGE READER “FREQUENCY RANGES” | ||
Generic | 902~928 (USA) | 865~868MHz (EU) |
Standard | 902.0-928.0 MHz (USA) | 865.6-867.6 MHz (Europe) |
902.0-928.0 MHz (Americas) | 865.0-867.0 MHz (India | |
920.0-926.0 MHz (Australia) | 866.0-867.6 MHz (Russian Federation) | |
920.5-924.5 MHz (China) | ||
919.0-923.0 MHz (Malaysia) | ||
921.5-928.0 MHz (New Zealand) | ||
920.0-925.0 MHz(Singapore) | ||
AIR INTERFACE PROTOCOL | ||
Protocol | EPC Gen II (ISO 18000 – 6C) | |
RF Power | 6dBM adjustable | |
Reading range | 6/8 Meters with Nundprox series of tags & cards, depending on vehicle type and installation conditions | |
ELECTRICAL | ||
Power input | 9 ~ 24 V DC, < 30mA | |
PoE | Optional | |
ACCESS CONTROLLER | ||
Doors | Single door controller incorporated, completely integrated | |
Users | 2100 (2000 +100 zone users) | |
Programming | Using Nundprox-W card | |
Outputs | Relay | NO, NC, Common |
Relay output time (Adjustable) | 0~99 Seconds, 5 seconds (Default) | |
Output load current for locking unit | 2.0Amp (max) | |
INTERFACE | ||
RS232 | USB | |
RS485 | Wi-Fi | |
TCP/IP | ||
GENERAL | ||
IP Rating | IP56 rated, Liquid from heavy seas or water projected from jets shall not enter the machine in any harmful quantity | |
Environment | Temperature | Operating 10°C ~ 55°C |
Storage 20°C ~ 75°C | ||
Humidity | 95% relative | |
Metrics | Size (Inchs) | 7.5 x 7.5 x 1.18 |
Weight | 2300grams (2.3Kg) | |
Indicator | LED, RGB | |
CERTIFICATION | ||
CE, according directive 2014/53/EU (RED) | ||
Electromagnetic Compatibility standard for radio equipment and services: Part 1 EN301489-1, Part 3 EN301489-3 | ||
WARRANTY | Warrantied against defects in materials and workmanship for 12/24 months. ( please visit https://nundnet.com/warranty) | |
APPLICATIONS | ||
Parking & Access Management etc. |
DOWNLOADS | ||||||
DESCRIPTION | CODE | SPECIFICATIONS | MANUAL | CERTIFICATIONS | ||
Integrated long range reader with built-in access control | NT I 9106 XY | Click here… | Click here… | CE, ISO | ||
X | A | 865~ 868 MHz., | ||||
B | 902 ~ 928 MHz | |||||
C | Customized | |||||
Y | D | RS232, RS 485, Wiegand | ||||
E | RS232, TCP/IP | |||||
F | RS232, WiFi | |||||
G | RS232, WiFi, TCP/IP | |||||
I | 5 | IP56 rated | ||||
6 | IP65 outdoor hood |
Additional information
INTERFACE | Nundnet NTI9106XY is developed & designed for easy integration into existing digital & electronic management systems in the industry, viz.a.viz access controls, car parking & vehicle access control, retail & property management, ID access control for offices and private buildings, Hand-free operation. Communication interfaces are RS 232, RS 485 for serial communication, open standard industrial protocol |
---|---|
MODULATION | Nundnet NTI9106XY uses Amplitude-shift keying (ASK), that represents the digital data as variations in the amplitude of a carrier wave. Here the binary symbol 1 is represented by transmitting a fixed-amplitude carrier wave & fixed frequency for a bit duration of T seconds. If the signal value is 1 then the carrier signal will be transmitted; otherwise, a signal value of 0 will be transmitted. This is the most sophisticated scheme of modulation which represent the data in groups using an additional amplitude levels |
ISO 18000-6B | It defines the air interface for radio frequency identification (RFID) devices operating in the 860 MHz ~ 960 MHz Industrial, Scientific, and Medical (ISM) band used in item management |
ISO 18000-6C | It defines air interface parameters for tags operating within the frequency range of 860–960 MHz and allows for use of different frequencies in different regions from within this range. Nundnet NT 915 P offers frequency range of 902~ 928 MHz, 865 ~ 868 MHz, 922 ~ 928 MHz. |
HOUSING | Nundnet NTI9106XY enclosure can be subjected to a jet of water from a nozzle of 6.3 mm diameter from all the directions. The test duration is 15 minutes for 12.5 liters per minute at pressure of 30 kPa at distance of 3 m. Hence IP 65 rating means that water cannot penetrate into the device in such a quantity or in such a position that can prove risky for operation of unit. IP66 insures the protection from total dust ingress & high pressure water jets from any direction. |
READING RANGE | Nundnet NTI9106XY are designed to sense Gen 2 EPC global are multiple frequencies from 860 ~ 960 MHz. Ultra High Frequency (UHF) Passive RFID Tags, and an ideal sensing range unto 20 Meters. |
FCC COMPLIANCE | Nundnet NTI9106XY equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. This device is designed to provide the reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. |